Contents
Images
Upload your image
DSS Images Other Images
Related articles
Effective temperature scale and bolometric corrections from 2MASS photometry We present a method to determine effective temperatures, angularsemi-diameters and bolometric corrections for population I and II FGKtype stars based on V and 2MASS IR photometry. Accurate calibration isaccomplished by using a sample of solar analogues, whose averagetemperature is assumed to be equal to the solar effective temperature of5777 K. By taking into account all possible sources of error we estimateassociated uncertainties to better than 1% in effective temperature andin the range 1.0-2.5% in angular semi-diameter for unreddened stars.Comparison of our new temperatures with other determinations extractedfrom the literature indicates, in general, remarkably good agreement.These results suggest that the effective temperaure scale of FGK starsis currently established with an accuracy better than 0.5%-1%. Theapplication of the method to a sample of 10 999 dwarfs in the Hipparcoscatalogue allows us to define temperature and bolometric correction (Kband) calibrations as a function of (V-K), [m/H] and log g. Bolometriccorrections in the V and K bands as a function of T_eff, [m/H] and log gare also given. We provide effective temperatures, angularsemi-diameters, radii and bolometric corrections in the V and K bandsfor the 10 999 FGK stars in our sample with the correspondinguncertainties.
| The Tokyo PMC catalog 90-93: Catalog of positions of 6649 stars observed in 1990 through 1993 with Tokyo photoelectric meridian circle The sixth annual catalog of the Tokyo Photoelectric Meridian Circle(PMC) is presented for 6649 stars which were observed at least two timesin January 1990 through March 1993. The mean positions of the starsobserved are given in the catalog at the corresponding mean epochs ofobservations of individual stars. The coordinates of the catalog arebased on the FK5 system, and referred to the equinox and equator ofJ2000.0. The mean local deviations of the observed positions from theFK5 catalog positions are constructed for the basic FK5 stars to comparewith those of the Tokyo PMC Catalog 89 and preliminary Hipparcos resultsof H30.
| UBV photometry of stars whose positions are accurately known. III UBV photometric observations of 417 stars at BD declination 35-49 degfrom the NPZT(74) catalog of Yasuda et al. (1982) and the AGK3R catalogof Corben (1978), obtained with the 40-cm Cassegrain reflector atKvistaberg Observatory during 1984-1985, are reported. The data arepresented in tables, and the mean errors per observation are given as0.016 mag in V, 0.011 mag in B-V, 0.012 mag in U-B for U less than 10,and 0.026 mag in U-B for U greater than 10.
|
Submit a new article
Related links
Submit a new link
Member of following groups:
|
Observation and Astrometry data
Constellation: | Ηρακλής |
Right ascension: | 16h55m05.79s |
Declination: | +46°55'39.5" |
Apparent magnitude: | 9.064 |
Proper motion RA: | -3.3 |
Proper motion Dec: | 3.9 |
B-T magnitude: | 9.451 |
V-T magnitude: | 9.096 |
Catalogs and designations:
|